Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.935
Filtrar
1.
J Neural Eng ; 21(2)2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38592090

RESUMO

Objective.The extended infomax algorithm for independent component analysis (ICA) can separate sub- and super-Gaussian signals but converges slowly as it uses stochastic gradient optimization. In this paper, an improved extended infomax algorithm is presented that converges much faster.Approach.Accelerated convergence is achieved by replacing the natural gradient learning rule of extended infomax by a fully-multiplicative orthogonal-group based update scheme of the ICA unmixing matrix, leading to an orthogonal extended infomax algorithm (OgExtInf). The computational performance of OgExtInf was compared with original extended infomax and with two fast ICA algorithms: the popular FastICA and Picard, a preconditioned limited-memory Broyden-Fletcher-Goldfarb-Shanno (L-BFGS) algorithm belonging to the family of quasi-Newton methods.Main results.OgExtInf converges much faster than original extended infomax. For small-size electroencephalogram (EEG) data segments, as used for example in online EEG processing, OgExtInf is also faster than FastICA and Picard.Significance.OgExtInf may be useful for fast and reliable ICA, e.g. in online systems for epileptic spike and seizure detection or brain-computer interfaces.


Assuntos
Algoritmos , Interfaces Cérebro-Computador , Eletroencefalografia , Aprendizagem , Distribuição Normal
2.
J Neural Eng ; 21(2)2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38565100

RESUMO

Objective. The extensive application of electroencephalography (EEG) in brain-computer interfaces (BCIs) can be attributed to its non-invasive nature and capability to offer high-resolution data. The acquisition of EEG signals is a straightforward process, but the datasets associated with these signals frequently exhibit data scarcity and require substantial resources for proper labeling. Furthermore, there is a significant limitation in the generalization performance of EEG models due to the substantial inter-individual variability observed in EEG signals.Approach. To address these issues, we propose a novel self-supervised contrastive learning framework for decoding motor imagery (MI) signals in cross-subject scenarios. Specifically, we design an encoder combining convolutional neural network and attention mechanism. In the contrastive learning training stage, the network undergoes training with the pretext task of data augmentation to minimize the distance between pairs of homologous transformations while simultaneously maximizing the distance between pairs of heterologous transformations. It enhances the amount of data utilized for training and improves the network's ability to extract deep features from original signals without relying on the true labels of the data.Main results. To evaluate our framework's efficacy, we conduct extensive experiments on three public MI datasets: BCI IV IIa, BCI IV IIb, and HGD datasets. The proposed method achieves cross-subject classification accuracies of 67.32%, 82.34%, and 81.13%on the three datasets, demonstrating superior performance compared to existing methods.Significance. Therefore, this method has great promise for improving the performance of cross-subject transfer learning in MI-based BCI systems.


Assuntos
Interfaces Cérebro-Computador , Aprendizagem , Eletroencefalografia , Imagens, Psicoterapia , Redes Neurais de Computação , Algoritmos
3.
Artigo em Inglês | MEDLINE | ID: mdl-38578854

RESUMO

Predicting the potential for recovery of motor function in stroke patients who undergo specific rehabilitation treatments is an important and major challenge. Recently, electroencephalography (EEG) has shown potential in helping to determine the relationship between cortical neural activity and motor recovery. EEG recorded in different states could more accurately predict motor recovery than single-state recordings. Here, we design a multi-state (combining eyes closed, EC, and eyes open, EO) fusion neural network for predicting the motor recovery of patients with stroke after EEG-brain-computer-interface (BCI) rehabilitation training and use an explainable deep learning method to identify the most important features of EEG power spectral density and functional connectivity contributing to prediction. The prediction accuracy of the multi-states fusion network was 82%, significantly improved compared with a single-state model. The neural network explanation result demonstrated the important region and frequency oscillation bands. Specifically, in those two states, power spectral density and functional connectivity were shown as the regions and bands related to motor recovery in frontal, central, and occipital. Moreover, the motor recovery relation in bands, the power spectrum density shows the bands at delta and alpha bands. The functional connectivity shows the delta, theta, and alpha bands in the EC state; delta, theta, and beta mid at the EO state are related to motor recovery. Multi-state fusion neural networks, which combine multiple states of EEG signals into a single network, can increase the accuracy of predicting motor recovery after BCI training, and reveal the underlying mechanisms of motor recovery in brain activity.


Assuntos
Interfaces Cérebro-Computador , Aprendizado Profundo , Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Humanos , Eletroencefalografia/métodos , Reabilitação do Acidente Vascular Cerebral/métodos
4.
J Neuroeng Rehabil ; 21(1): 48, 2024 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-38581031

RESUMO

BACKGROUND: This research focused on the development of a motor imagery (MI) based brain-machine interface (BMI) using deep learning algorithms to control a lower-limb robotic exoskeleton. The study aimed to overcome the limitations of traditional BMI approaches by leveraging the advantages of deep learning, such as automated feature extraction and transfer learning. The experimental protocol to evaluate the BMI was designed as asynchronous, allowing subjects to perform mental tasks at their own will. METHODS: A total of five healthy able-bodied subjects were enrolled in this study to participate in a series of experimental sessions. The brain signals from two of these sessions were used to develop a generic deep learning model through transfer learning. Subsequently, this model was fine-tuned during the remaining sessions and subjected to evaluation. Three distinct deep learning approaches were compared: one that did not undergo fine-tuning, another that fine-tuned all layers of the model, and a third one that fine-tuned only the last three layers. The evaluation phase involved the exclusive closed-loop control of the exoskeleton device by the participants' neural activity using the second deep learning approach for the decoding. RESULTS: The three deep learning approaches were assessed in comparison to an approach based on spatial features that was trained for each subject and experimental session, demonstrating their superior performance. Interestingly, the deep learning approach without fine-tuning achieved comparable performance to the features-based approach, indicating that a generic model trained on data from different individuals and previous sessions can yield similar efficacy. Among the three deep learning approaches compared, fine-tuning all layer weights demonstrated the highest performance. CONCLUSION: This research represents an initial stride toward future calibration-free methods. Despite the efforts to diminish calibration time by leveraging data from other subjects, complete elimination proved unattainable. The study's discoveries hold notable significance for advancing calibration-free approaches, offering the promise of minimizing the need for training trials. Furthermore, the experimental evaluation protocol employed in this study aimed to replicate real-life scenarios, granting participants a higher degree of autonomy in decision-making regarding actions such as walking or stopping gait.


Assuntos
Interfaces Cérebro-Computador , Aprendizado Profundo , Exoesqueleto Energizado , Humanos , Algoritmos , Extremidade Inferior , Eletroencefalografia/métodos
5.
Sensors (Basel) ; 24(7)2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38610540

RESUMO

In the field of neuroscience, brain-computer interfaces (BCIs) are used to connect the human brain with external devices, providing insights into the neural mechanisms underlying cognitive processes, including aesthetic perception. Non-invasive BCIs, such as EEG and fNIRS, are critical for studying central nervous system activity and understanding how individuals with cognitive deficits process and respond to aesthetic stimuli. This study assessed twenty participants who were divided into control and impaired aging (AI) groups based on MMSE scores. EEG and fNIRS were used to measure their neurophysiological responses to aesthetic stimuli that varied in pleasantness and dynamism. Significant differences were identified between the groups in P300 amplitude and late positive potential (LPP), with controls showing greater reactivity. AI subjects showed an increase in oxyhemoglobin in response to pleasurable stimuli, suggesting hemodynamic compensation. This study highlights the effectiveness of multimodal BCIs in identifying the neural basis of aesthetic appreciation and impaired aging. Despite its limitations, such as sample size and the subjective nature of aesthetic appreciation, this research lays the groundwork for cognitive rehabilitation tailored to aesthetic perception, improving the comprehension of cognitive disorders through integrated BCI methodologies.


Assuntos
Interfaces Cérebro-Computador , Humanos , Envelhecimento , Encéfalo , Estética , Percepção
6.
J Neural Eng ; 21(2)2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38579696

RESUMO

Objective.Artificial neural networks (ANNs) are state-of-the-art tools for modeling and decoding neural activity, but deploying them in closed-loop experiments with tight timing constraints is challenging due to their limited support in existing real-time frameworks. Researchers need a platform that fully supports high-level languages for running ANNs (e.g. Python and Julia) while maintaining support for languages that are critical for low-latency data acquisition and processing (e.g. C and C++).Approach.To address these needs, we introduce the Backend for Realtime Asynchronous Neural Decoding (BRAND). BRAND comprises Linux processes, termednodes, which communicate with each other in agraphvia streams of data. Its asynchronous design allows for acquisition, control, and analysis to be executed in parallel on streams of data that may operate at different timescales. BRAND uses Redis, an in-memory database, to send data between nodes, which enables fast inter-process communication and supports 54 different programming languages. Thus, developers can easily deploy existing ANN models in BRAND with minimal implementation changes.Main results.In our tests, BRAND achieved <600 microsecond latency between processes when sending large quantities of data (1024 channels of 30 kHz neural data in 1 ms chunks). BRAND runs a brain-computer interface with a recurrent neural network (RNN) decoder with less than 8 ms of latency from neural data input to decoder prediction. In a real-world demonstration of the system, participant T11 in the BrainGate2 clinical trial (ClinicalTrials.gov Identifier: NCT00912041) performed a standard cursor control task, in which 30 kHz signal processing, RNN decoding, task control, and graphics were all executed in BRAND. This system also supports real-time inference with complex latent variable models like Latent Factor Analysis via Dynamical Systems.Significance.By providing a framework that is fast, modular, and language-agnostic, BRAND lowers the barriers to integrating the latest tools in neuroscience and machine learning into closed-loop experiments.


Assuntos
Interfaces Cérebro-Computador , Neurociências , Humanos , Redes Neurais de Computação
7.
Artigo em Inglês | MEDLINE | ID: mdl-38598402

RESUMO

Canonical correlation analysis (CCA), Multivariate synchronization index (MSI), and their extended methods have been widely used for target recognition in Brain-computer interfaces (BCIs) based on Steady State Visual Evoked Potentials (SSVEP), and covariance calculation is an important process for these algorithms. Some studies have proved that embedding time-local information into the covariance can optimize the recognition effect of the above algorithms. However, the optimization effect can only be observed from the recognition results and the improvement principle of time-local information cannot be explained. Therefore, we propose a time-local weighted transformation (TT) recognition framework that directly embeds the time-local information into the electroencephalography signal through weighted transformation. The influence mechanism of time-local information on the SSVEP signal can then be observed in the frequency domain. Low-frequency noise is suppressed on the premise of sacrificing part of the SSVEP fundamental frequency energy, the harmonic energy of SSVEP is enhanced at the cost of introducing a small amount of high-frequency noise. The experimental results show that the TT recognition framework can significantly improve the recognition ability of the algorithms and the separability of extracted features. Its enhancement effect is significantly better than the traditional time-local covariance extraction method, which has enormous application potential.


Assuntos
Interfaces Cérebro-Computador , Humanos , Potenciais Evocados Visuais , Reconhecimento Automatizado de Padrão/métodos , Reconhecimento Psicológico , Eletroencefalografia/métodos , Algoritmos , Estimulação Luminosa
8.
Artigo em Inglês | MEDLINE | ID: mdl-38598403

RESUMO

Steady-state visual evoked potential (SSVEP), one of the most popular electroencephalography (EEG)-based brain-computer interface (BCI) paradigms, can achieve high performance using calibration-based recognition algorithms. As calibration-based recognition algorithms are time-consuming to collect calibration data, the least-squares transformation (LST) has been used to reduce the calibration effort for SSVEP-based BCI. However, the transformation matrices constructed by current LST methods are not precise enough, resulting in large differences between the transformed data and the real data of the target subject. This ultimately leads to the constructed spatial filters and reference templates not being effective enough. To address these issues, this paper proposes multi-stimulus LST with online adaptation scheme (ms-LST-OA). METHODS: The proposed ms-LST-OA consists of two parts. Firstly, to improve the precision of the transformation matrices, we propose the multi-stimulus LST (ms-LST) using cross-stimulus learning scheme as the cross-subject data transformation method. The ms-LST uses the data from neighboring stimuli to construct a higher precision transformation matrix for each stimulus to reduce the differences between transformed data and real data. Secondly, to further optimize the constructed spatial filters and reference templates, we use an online adaptation scheme to learn more features of the EEG signals of the target subject through an iterative process trial-by-trial. RESULTS: ms-LST-OA performance was measured for three datasets (Benchmark Dataset, BETA Dataset, and UCSD Dataset). Using few calibration data, the ITR of ms-LST-OA achieved 210.01±10.10 bits/min, 172.31±7.26 bits/min, and 139.04±14.90 bits/min for all three datasets, respectively. CONCLUSION: Using ms-LST-OA can reduce calibration effort for SSVEP-based BCIs.


Assuntos
Interfaces Cérebro-Computador , Potenciais Evocados Visuais , Humanos , Calibragem , Estimulação Luminosa/métodos , Eletroencefalografia/métodos , Algoritmos
9.
J Neuroeng Rehabil ; 21(1): 61, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658998

RESUMO

BACKGROUND: Brain-computer interface (BCI) technology offers children with quadriplegic cerebral palsy unique opportunities for communication, environmental exploration, learning, and game play. Research in adults demonstrates a negative impact of fatigue on BCI enjoyment, while effects on BCI performance are variable. To date, there have been no pediatric studies of BCI fatigue. The purpose of this study was to assess the effects of two different BCI paradigms, motor imagery and visual P300, on the development of self-reported fatigue and an electroencephalography (EEG) biomarker of fatigue in typically developing children. METHODS: Thirty-seven typically-developing school-aged children were recruited to a prospective, crossover study. Participants attended three sessions: (A) motor imagery-BCI, (B) visual P300-BCI, and (C) video viewing (control). The motor imagery task involved an imagined left- or right-hand squeeze. The P300 task involved attending to one square on a 3 × 3 grid during a random single flash sequence. Each paradigm had respective calibration periods and a similar visual counting game. Primary outcomes were self-reported fatigue and the power of the EEG alpha band both collected during resting-state periods pre- and post-task. Self-reported fatigue was measured using a 10-point visual analog scale. EEG alpha band power was calculated as the integrated power spectral density from 8 to 12 Hz of the EEG spectrum. RESULTS: Thirty-two children completed the protocol (age range 7-16, 63% female). Self-reported fatigue and EEG alpha band power increased across all sessions (F(1,155) = 33.9, p < 0.001; F = 5.0(1,149), p = 0.027 respectively). No differences in fatigue development were observed between session types. There was no correlation between self-reported fatigue and EEG alpha band power change. BCI performance varied between participants and paradigms as expected but was not associated with self-reported fatigue or EEG alpha band power. CONCLUSION: Short periods (30-mintues) of BCI use can increase self-reported fatigue and EEG alpha band power to a similar degree in children performing motor imagery and P300 BCI paradigms. Performance was not associated with our measures of fatigue; the impact of fatigue on useability and enjoyment is unclear. Our results reflect the variability of fatigue and the BCI experience more broadly in children and warrant further investigation.


Assuntos
Interfaces Cérebro-Computador , Eletroencefalografia , Potenciais Evocados P300 , Fadiga , Imaginação , Humanos , Criança , Masculino , Feminino , Potenciais Evocados P300/fisiologia , Fadiga/fisiopatologia , Fadiga/psicologia , Imaginação/fisiologia , Estudos Cross-Over , Adolescente , Estudos Prospectivos
10.
Sci Rep ; 14(1): 9281, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38654008

RESUMO

Steady-state visual evoked potentials (SSVEP) are electroencephalographic signals elicited when the brain is exposed to a visual stimulus with a steady frequency. We analyzed the temporal dynamics of SSVEP during sustained flicker stimulation at 5, 10, 15, 20 and 40 Hz. We found that the amplitudes of the responses were not stable over time. For a 5 Hz stimulus, the responses progressively increased, while, for higher flicker frequencies, the amplitude increased during the first few seconds and often showed a continuous decline afterward. We hypothesize that these two distinct sets of frequency-dependent SSVEP signal properties reflect the contribution of parvocellular and magnocellular visual pathways generating sustained and transient responses, respectively. These results may have important applications for SSVEP signals used in research and brain-computer interface technology and may contribute to a better understanding of the frequency-dependent temporal mechanisms involved in the processing of prolonged periodic visual stimuli.


Assuntos
Eletroencefalografia , Potenciais Evocados Visuais , Estimulação Luminosa , Potenciais Evocados Visuais/fisiologia , Humanos , Masculino , Feminino , Adulto , Adulto Jovem , Interfaces Cérebro-Computador , Córtex Visual/fisiologia
11.
Artigo em Inglês | MEDLINE | ID: mdl-38619940

RESUMO

Affective brain-computer interfaces (aBCIs) have garnered widespread applications, with remarkable advancements in utilizing electroencephalogram (EEG) technology for emotion recognition. However, the time-consuming process of annotating EEG data, inherent individual differences, non-stationary characteristics of EEG data, and noise artifacts in EEG data collection pose formidable challenges in developing subject-specific cross-session emotion recognition models. To simultaneously address these challenges, we propose a unified pre-training framework based on multi-scale masked autoencoders (MSMAE), which utilizes large-scale unlabeled EEG signals from multiple subjects and sessions to extract noise-robust, subject-invariant, and temporal-invariant features. We subsequently fine-tune the obtained generalized features with only a small amount of labeled data from a specific subject for personalization and enable cross-session emotion recognition. Our framework emphasizes: 1) Multi-scale representation to capture diverse aspects of EEG signals, obtaining comprehensive information; 2) An improved masking mechanism for robust channel-level representation learning, addressing missing channel issues while preserving inter-channel relationships; and 3) Invariance learning for regional correlations in spatial-level representation, minimizing inter-subject and inter-session variances. Under these elaborate designs, the proposed MSMAE exhibits a remarkable ability to decode emotional states from a different session of EEG data during the testing phase. Extensive experiments conducted on the two publicly available datasets, i.e., SEED and SEED-IV, demonstrate that the proposed MSMAE consistently achieves stable results and outperforms competitive baseline methods in cross-session emotion recognition.


Assuntos
Algoritmos , Interfaces Cérebro-Computador , Eletroencefalografia , Emoções , Humanos , Emoções/fisiologia , Eletroencefalografia/métodos , Feminino , Masculino , Aprendizado de Máquina , Artefatos , Adulto , Redes Neurais de Computação
12.
Artigo em Inglês | MEDLINE | ID: mdl-38625770

RESUMO

This study embarks on a comprehensive investigation of the effectiveness of repetitive transcranial direct current stimulation (tDCS)-based neuromodulation in augmenting steady-state visual evoked potential (SSVEP) brain-computer interfaces (BCIs), alongside exploring pertinent electroencephalography (EEG) biomarkers for assessing brain states and evaluating tDCS efficacy. EEG data were garnered across three distinct task modes (eyes open, eyes closed, and SSVEP stimulation) and two neuromodulation patterns (sham-tDCS and anodal-tDCS). Brain arousal and brain functional connectivity were measured by extracting features of fractal EEG and information flow gain, respectively. Anodal-tDCS led to diminished offsets and enhanced information flow gains, indicating improvements in both brain arousal and brain information transmission capacity. Additionally, anodal-tDCS markedly enhanced SSVEP-BCIs performance as evidenced by increased amplitudes and accuracies, whereas sham-tDCS exhibited lesser efficacy. This study proffers invaluable insights into the application of neuromodulation methods for bolstering BCI performance, and concurrently authenticates two potent electrophysiological markers for multifaceted characterization of brain states.


Assuntos
Interfaces Cérebro-Computador , Eletroencefalografia , Potenciais Evocados Visuais , Fractais , Estimulação Transcraniana por Corrente Contínua , Humanos , Estimulação Transcraniana por Corrente Contínua/métodos , Potenciais Evocados Visuais/fisiologia , Masculino , Adulto , Feminino , Adulto Jovem , Nível de Alerta/fisiologia , Encéfalo/fisiologia , Voluntários Saudáveis , Algoritmos
13.
Sci Adv ; 10(15): eadm8246, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38608024

RESUMO

Temporally coordinated neural activity is central to nervous system function and purposeful behavior. Still, there is a paucity of evidence demonstrating how this coordinated activity within cortical and subcortical regions governs behavior. We investigated this between the primary motor (M1) and contralateral cerebellar cortex as rats learned a neuroprosthetic/brain-machine interface (BMI) task. In neuroprosthetic task, actuator movements are causally linked to M1 "direct" neurons that drive the decoder for successful task execution. However, it is unknown how task-related M1 activity interacts with the cerebellum. We observed a notable 3 to 6 hertz coherence that emerged between these regions' local field potentials (LFPs) with learning that also modulated task-related spiking. We identified robust task-related indirect modulation in the cerebellum, which developed a preferential relationship with M1 task-related activity. Inhibiting cerebellar cortical and deep nuclei activity through optogenetics led to performance impairments in M1-driven neuroprosthetic control. Together, these results demonstrate that cerebellar influence is necessary for M1-driven neuroprosthetic control.


Assuntos
Interfaces Cérebro-Computador , Cerebelo , Animais , Ratos , Núcleo Celular , Aprendizagem , Movimento
14.
Sci Rep ; 14(1): 9221, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649681

RESUMO

Technological advances in head-mounted displays (HMDs) facilitate the acquisition of physiological data of the user, such as gaze, pupil size, or heart rate. Still, interactions with such systems can be prone to errors, including unintended behavior or unexpected changes in the presented virtual environments. In this study, we investigated if multimodal physiological data can be used to decode error processing, which has been studied, to date, with brain signals only. We examined the feasibility of decoding errors solely with pupil size data and proposed a hybrid decoding approach combining electroencephalographic (EEG) and pupillometric signals. Moreover, we analyzed if hybrid approaches can improve existing EEG-based classification approaches and focused on setups that offer increased usability for practical applications, such as the presented game-like virtual reality flight simulation. Our results indicate that classifiers trained with pupil size data can decode errors above chance. Moreover, hybrid approaches yielded improved performance compared to EEG-based decoders in setups with a reduced number of channels, which is crucial for many out-of-the-lab scenarios. These findings contribute to the development of hybrid brain-computer interfaces, particularly in combination with wearable devices, which allow for easy acquisition of additional physiological data.


Assuntos
Interfaces Cérebro-Computador , Eletroencefalografia , Pupila , Realidade Virtual , Humanos , Eletroencefalografia/métodos , Adulto , Masculino , Pupila/fisiologia , Feminino , Adulto Jovem , Simulação por Computador , Encéfalo/fisiologia , Frequência Cardíaca/fisiologia
15.
Artigo em Inglês | MEDLINE | ID: mdl-38502615

RESUMO

Motor brain-computer interfaces (BCIs) have gained growing research interest in motor rehabilitation, restoration, and prostheses control. Decoding upper-limb movement direction with noninvasive BCIs has been extensively investigated. However, few of them address the intervention of cognitive distraction that impairs decoding performance in practice. In this study, we propose a novel decoding model with invariant patterns in embedding manifold on a mixed dataset pooled from electroencephalograph (EEG) signals under different attentional states. We reconstruct an embedding low-dimensional manifold that intrinsically characterizes movements of the upper limb and transfer patterns of neural activities decomposed from brain functional connectivity (FC) to the manifold subspace to further preserve movement-related information. Experimental results showed that the proposed decoding model had higher robustness on the mixed dataset of attentive and distracted states compared to the baseline method. Our research provides insights into modeling a uniform underlying mechanism of movement-related EEG signals and can help enhance the practicability of BCI systems under real-world situations.


Assuntos
Interfaces Cérebro-Computador , Extremidade Superior , Humanos , Movimento , Eletroencefalografia/métodos , Cognição
16.
Artigo em Inglês | MEDLINE | ID: mdl-38512735

RESUMO

Brain-computer interfaces (BCIs) are anticipated to improve the efficacy of rehabilitation for people with motor disabilities. However, applying BCI in clinical practice is still a challenge due to the great diversity of patients. In the current study, a novel action observation (AO) based BCI was proposed and tested on stroke patients. Ten non-hemineglect patients and ten hemineglect patients were recruited. Four AO stimuli were designed, each presenting a decomposed action to complete the reach-and-grasp task. EEG data and eye movement data were collected. Eye movement data was utilized to analyze the reasons for individual differences in BCI performance. Task discriminative component analysis was utilized to perform online target detection. The results showed that the designed AO-based BCI could simultaneously induce steady state motion visual evoked potential (SSMVEP) from the occipital region and sensory motor rhythm from the sensorimotor region in stroke patients. The average online detection accuracy among the four AO stimuli reached 67% within 3 s in the non-hemineglect group, while the accuracy only reached 35% in the hemineglect group. Gaze metrics showed that the average total duration of fixations during the stimulus phase in the hemineglect group was only 1.31 s ± 0.532 s which was significantly lower than that in the non-hemineglect group. The results indicated that hemineglect patients have difficulty gazing at the AO stimulus, resulting in poor detection performance and weak desynchronization in the sensorimotor region. Furthermore, the degree of neglect is inversely proportional to the target detection accuracy in hemineglect stroke patients. In addition, the gaze metrics associated with cognitive load were significantly correlated with the accuracy in non-hemineglect patients. It indicated the cognitive load may affect the AO-based BCI. The current study will expedite the clinical application of AO-based BCI.


Assuntos
Interfaces Cérebro-Computador , Acidente Vascular Cerebral , Humanos , Potenciais Evocados Visuais , Movimentos Oculares , Eletroencefalografia/métodos
17.
Sensors (Basel) ; 24(6)2024 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-38544185

RESUMO

This paper explores the potential benefits of integrating a brain-computer interface (BCI) utilizing the visual-evoked potential paradigm (SSVEP) with a six-degrees-of-freedom (6-DOF) robotic arm to enhance rehabilitation tools. The SSVEP-BCI employs electroencephalography (EEG) as a method of measuring neural responses inside the occipital lobe in reaction to pre-established visual stimulus frequencies. The BCI offline and online studies yielded accuracy rates of 75% and 83%, respectively, indicating the efficacy of the system in accurately detecting and capturing user intent. The robotic arm achieves planar motion by utilizing a total of five control frequencies. The results of this experiment exhibited a high level of precision and consistency, as indicated by the recorded values of ±0.85 and ±1.49 cm for accuracy and repeatability, respectively. Moreover, during the performance tests conducted with the task of constructing a square within each plane, the system demonstrated accuracy of 79% and 83%. The use of SSVEP-BCI and a robotic arm together shows promise and sets a solid foundation for the development of assistive technologies that aim to improve the health of people with amyotrophic lateral sclerosis, spina bifida, and other related diseases.


Assuntos
Interfaces Cérebro-Computador , Procedimentos Cirúrgicos Robóticos , Tecnologia Assistiva , Humanos , Eletroencefalografia/métodos , Potenciais Evocados Visuais , Estimulação Luminosa
18.
J Neural Eng ; 21(2)2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38513290

RESUMO

Objective.Code-modulated visual evoked potential (c-VEP) based brain-computer interfaces (BCIs) exhibit high encoding efficiency. Nevertheless, the majority of c-VEP based BCIs necessitate an initial training or calibration session, particularly when the number of targets expands, which impedes the practicality. To address this predicament, this study introduces a calibration-free c-VEP based BCI employing narrow-band random sequences.Approach.For the encoding method, a series of random sequences were generated within a specific frequency band. The c-VEP signals were subsequently elicited through the application of on-type grid flashes that were modulated by these sequences. For the calibration-free decoding algorithm, filter-bank canonical correlation analysis (FBCCA) was utilized with the reference templates generated from the original sequences. Thirty-five subjects participated into an online BCI experiment. The performances of c-VEP based BCIs utilizing narrow-band random sequences with frequency bands of 15-25 Hz (NBRS-15) and 8-16 Hz (NBRS-8) were compared with that of a steady-state visual evoked potential (SSVEP) based BCI within a frequency range of 8-15.8 Hz.Main results.The offline analysis results demonstrated a substantial correlation between the c-VEPs and the original narrow-band random sequences. After parameter optimization, the calibration-free system employing the NBRS-15 frequency band achieved an average information transfer rate (ITR) of 78.56 ± 37.03 bits/min, which exhibited no significant difference compared to the performance of the SSVEP based system when utilizing FBCCA. The proposed system achieved an average ITR of 102.1 ± 57.59 bits/min in a simulation of a 1000-target BCI system.Significance.This study introduces a novel calibration-free c-VEP based BCI system employing narrow-band random sequences and shows great potential of the proposed system in achieving a large number of targets and high ITR.


Assuntos
Interfaces Cérebro-Computador , Potenciais Evocados Visuais , Humanos , Eletroencefalografia/métodos , Calibragem , Algoritmos , Estimulação Luminosa
19.
Artigo em Inglês | MEDLINE | ID: mdl-38517720

RESUMO

Steady-state visual evoked potential (SSVEP)-based brain-computer interfaces (BCIs) have emerged as a prominent technology due to their high information transfer rate, rapid calibration time, and robust signal-to-noise ratio. However, a critical challenge for practical applications is performance degradation caused by user fatigue during prolonged use. This work proposes novel methods to address this challenge by dynamically adjusting data acquisition length and updating detection models based on a fatigue-aware stopping strategy. Two 16-target SSVEP-BCIs were employed, one using low-frequency and the other using high-frequency stimulation. A self-recorded fatigue dataset from 24 subjects was utilized for extensive evaluation. A simulated online experiment demonstrated that the proposed methods outperform the conventional fixed stopping strategy in terms of classification accuracy, information transfer rate, and selection time, irrespective of stimulation frequency. These findings suggest that the proposed approach can significantly improve SSVEP-BCI performance under fatigue conditions, leading to superior performance during extended use.


Assuntos
Interfaces Cérebro-Computador , Humanos , Eletroencefalografia/métodos , Potenciais Evocados Visuais , Estimulação Luminosa/métodos , Fadiga , Algoritmos
20.
J Neural Eng ; 21(2)2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38537269

RESUMO

Objective. Brain-computer interfaces (BCIs) are neuroprosthetic devices that allow for direct interaction between brains and machines. These types of neurotechnologies have recently experienced a strong drive in research and development, given, in part, that they promise to restore motor and communication abilities in individuals experiencing severe paralysis. While a rich literature analyzes the ethical, legal, and sociocultural implications (ELSCI) of these novel neurotechnologies, engineers, clinicians and BCI practitioners often do not have enough exposure to these topics.Approach. Here, we present the IEEE Neuroethics Framework, an international, multiyear, iterative initiative aimed at developing a robust, accessible set of considerations for diverse stakeholders.Main results. Using the framework, we provide practical examples of ELSCI considerations for BCI neurotechnologies. We focus on invasive technologies, and in particular, devices that are implanted intra-cortically for medical research applications.Significance. We demonstrate the utility of our framework in exposing a wide range of implications across different intra-cortical BCI technology modalities and conclude with recommendations on how to utilize this knowledge in the development and application of ethical guidelines for BCI neurotechnologies.


Assuntos
Interfaces Cérebro-Computador , Neurociências , Humanos , Encéfalo , Paralisia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...